R&D Center
This is the NSV R&D center, which leads technical
development in the noise, vibration, and shock fields.
Earthquake-Proof System Development
EARTHQUAKE-PROOF SYSTEM DEVELOPMENT
Earthquake-Proof System Development
Earthquake-Proof System Development

A seismic system has been installed in major facilities and firefighting facilities and application of optimized seismic system by seismic system calculation and test

Necessity
01
Disaster Prevention
We prevent damage to human life and preserve property value by minimizing damage to structures and major facilities when an earthquake breaks out.
Examination of seismic adequacy of major facilities and pipe
02
Pre-examination
Examination of earthquake damage and seismic influence in major facilities of business sites
03
Optimal Measures
Seismic design in major facilities of business sites
Seismic performance test condition
1 ~ 50Hz
Spectrum Damping Application Value: 2% [General application, seismic test method and specifications for electric communication facilities]
Design Spectrum: S Class applied
Model X, Y [Horizontal] Z [Vertical]
Seismic Class S
Required Response Spectrum (Seismic Class S Damping 2%)
Test Structure
2Ton structure (based on general air conditioning equipment)
Target Seismic Product
[Wire Mount] VWM
KTL Seismic Experiment Video
Result of structural soundness check after repeating two seismic tests
Item Result Remarks
Specimen one-way maximum displacement 14.4mm
Overturn or fall of equipment under test Test OK
Breakaway of floor fixing part of equipment under test Test OK
Breakaway of installed components Test OK
Frame deformation or damage of equipment under test Test OK
Crack, deformation, or cutting of fixing devices such as anchorings or bolts Test OK
Other deformation or damage which is identifiable with the naked eyes Test OK
Target Seismic Product
[Restrained Spring Mount] SFSL
[Seismic Stopper] NSS-E, F
Product Test Video
Result of structural soundness check after repeating two seismic tests
Item Result Remarks
Specimen one-way maximum displacement 9.3mm
Overturn or fall of equipment under test Test OK
Breakaway of floor fixing part of equipment under test Test OK
Breakaway of installed components Test OK
Frame deformation or damage of equipment under test Test OK
Crack, deformation, and cutting of fixing devices such as anchorings or bolts Test OK
Other deformation or damage which is identifiable with the naked eyes Test OK