- Recruitment
- Right people for NSV
- NSV PEOPLE
- Task
- HR System Welfare
A seismic system has been installed in major facilities and firefighting facilities and application of optimized seismic system by seismic system calculation and test
Model | X, Y [Horizontal] | Z [Vertical] |
Seismic Class S |
![]() |
![]() |
Item | Result | Remarks |
---|---|---|
Specimen one-way maximum displacement | 14.4mm | |
Overturn or fall of equipment under test | Test OK | |
Breakaway of floor fixing part of equipment under test | Test OK | |
Breakaway of installed components | Test OK | |
Frame deformation or damage of equipment under test | Test OK | |
Crack, deformation, or cutting of fixing devices such as anchorings or bolts | Test OK | |
Other deformation or damage which is identifiable with the naked eyes | Test OK |
Item | Result | Remarks |
---|---|---|
Specimen one-way maximum displacement | 9.3mm | |
Overturn or fall of equipment under test | Test OK | |
Breakaway of floor fixing part of equipment under test | Test OK | |
Breakaway of installed components | Test OK | |
Frame deformation or damage of equipment under test | Test OK | |
Crack, deformation, and cutting of fixing devices such as anchorings or bolts | Test OK | |